Vaillant VRC 430f Instalační manuál Strana 1

Procházejte online nebo si stáhněte Instalační manuál pro Termostaty Vaillant VRC 430f. Vaillant VRC 430f Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - VRC 430f

For the operator / for the heating engineerOperating and Installation ManualVRC 430fWeather compensator controller with radio transmissionVRC 430fGB

Strany 2

Operating instructions VRC 430f 0020042470_0110 Click the right-hand dial.The parameter value marked by the cursor is highlight-ed.Th. 12.01.0611:46

Strany 3

11Operating instructions VRC 430f 0020042470_01Changing parameters in the basic displayParameter MeaningHeating circuit 1 (HC1)Room target temperatur

Strany 4 - Equipment properties

Operating instructions VRC 430f 0020042470_0112Changing the operating mode in the default displayOperating modeMeaningAuto(matic) The heating circuit

Strany 5 - Safety 2

13Operating instructions VRC 430f 0020042470_0108:00 12:0015 °20 °25 °Room temperatureTimePeriod08:00 12:0015 °20 °25 °TimePeriod2341Set backtemperat

Strany 6 - 3 Notes on operation

Operating instructions VRC 430f 0020042470_0114Screen Title screenadjustableoperating values(only display = A)Remarks Unit Min.valueMax.valueStep dis

Strany 7

15Operating instructions VRC 430f 0020042470_01Screen Title screenadjustableoperating values(only display = A)Remarks Unit Min.valueMax.valueStep dis

Strany 8

Operating instructions VRC 430f 0020042470_0116The end time for window 1 should be set similarly.The comfort temperature for time window 1 is set as

Strany 9

17Operating instructions VRC 430f 0020042470_01The desired room target temperature or the frost pro-tection function is set. The display changes from

Strany 10 - 4 Operation

Operating instructions VRC 430f 0020042470_0118The required heating curve is set. The display changes from highlighted to normal.4.7.4 Entering para

Strany 11 - Auto 19.0 °C

19Operating instructions VRC 430f 0020042470_015 Status and error messagesStatus and error messages are displayed in the second row of the field for

Strany 13 - Operation 4

Operating instructions VRC 430f 0020042470_0120 Mount four new batteries of the same type into the battery compartment on the reverse side of the co

Strany 14

For the heating engineerInstallation instructionsVRC 430fVRC 430fWeather compensator controller with radio transmissionContents1 Notes on the documen

Strany 15

Installation instructions VRC 430f 0020042470_0121 Notes on the documentationThe following notes are intended to help you throughout the entire doc

Strany 16

3Installation instructions VRC 430f 0020042470_011234Fig. 2.1 System drawingKey1 VRC 430f2 Radio outdoor sensor VR 20 or VR 21 (DCF)3 Boiler4 Radio

Strany 17 - Operation 4

Installation instructions VRC 430f 0020042470_0143 Safety instructions and regulationsThe VRC 430f must be installed by a suitably qualified heatin

Strany 18

5Installation instructions VRC 430f 0020042470_014 AssemblyThe VRC 430f must be installed on a wall in the living area. The VRC 430f is supplied with

Strany 19 - Status and error messages 5

Installation instructions VRC 430f 0020042470_016 Check whether the green LED lights up at the radio receiver unit after a short period of time. C

Strany 20 - 5 Status and error messages

7Installation instructions VRC 430f 0020042470_0112Fig. 4.3 Installing the wall mount Drill two holes with diameter 6 mm to match the fix-ing holes.

Strany 21

Installation instructions VRC 430f 0020042470_018Proceed as follows: Pull the controller (1) off the wall socket (2). This can be done by pushing a

Strany 22 - 1 Notes on the documentation

9Installation instructions VRC 430f 0020042470_0112Fig. 5.1 Radio receiver electrical connectionsKey1 Terminal rail for the wireless unit wall plint

Strany 23

For the operatorOperating instructionsVRC 430fVRC 430fWeather compensator controller with radio transmissionContentsEquipment properties ...

Strany 24

Installation instructions VRC 430f 0020042470_0110The quality of the wireless data communication for out-door sensors and controllers is represented

Strany 25 - Assembly 4

11Installation instructions VRC 430f 0020042470_01Code layerenable 15Code number0 0 0 0> Enter codeFig. 6.3 Screen 15The default code is 1 0 0

Strany 26 - 4 Assembly

Installation instructions VRC 430f 0020042470_0112Screen Title screenadjustableoperating values(only display = A)Remarks Unit Min.valueMax.valueIncr

Strany 27 - Assembly 4

13Installation instructions VRC 430f 0020042470_01Screen Title screenadjustableoperating values(only display = A)Remarks Unit Min.valueMax.valueIncre

Strany 28 - 5 Installation

Installation instructions VRC 430f 0020042470_01146.4 Function floor dryingThe floor-drying function is used to "heat dry” a freshly-laid heati

Strany 29 - Initial commissioning 6

15Installation instructions VRC 430f 0020042470_017 Factory customer service, manufacturer's guarantee7.1 Vaillant ServiceTo ensure regular ser

Strany 30 - 6 Initial commissioning

Installation instructions VRC 430f 0020042470_01169 Technical dataParameter VRC 430fOperating voltage Umax 4x1.5 V (AA)Service life of battery (alka

Strany 31 - Initial commissioning 6

17Installation instructions VRC 430f 0020042470_01Glossaryset-back tempThe set-back temperature is the reduced interior tem-perature maintained by yo

Strany 32 - If outdoor temperature

Installation instructions VRC 430f 0020042470_0118Heating curveA heating curve shows the relationship between the out-side temperature and the flow

Strany 33

19Installation instructions VRC 430f 0020042470_01heating flow temperature is adjusted in the event of deviation.– ThermostatThe in-built temperature

Strany 34

Operating instructions VRC 430f 0020042470_014Equipment propertiesApplicationThe VRC 430f is a weather compensator controller for heating and water h

Strany 36 - 9 Technical data

5Operating instructions VRC 430f 0020042470_011 Notes on the documentationThe following notes are intended to help you throughout the entire documen

Strany 37 - Glossary

Operating instructions VRC 430f 0020042470_0163 Notes on operation3 Notes on operation3.1 Intended useThe VRC 430f controller has been built using s

Strany 38

7Operating instructions VRC 430f 0020042470_014 Operationh Note! Ask the heating engineer to explain how to use the unit after it has been installed.

Strany 39 - Appendix

Operating instructions VRC 430f 0020042470_0184.2 Overview of the display (field)The parameters and settings (operating values) of the VRC 430f are

Strany 40 - 0020042470_01 GB 092008

9Operating instructions VRC 430f 0020042470_014.3.1 Show various screensBy turning the left-hand dial you can page through the individual screens of

Komentáře k této Příručce

Žádné komentáře